Question 3
What is the battery drain of the fridge?
The power consumption of the RF47 (BD35 compressor)
measured on average over a 24 hour period is as follows:-
Ambient
Temperature
Freezer
Temperature
Fridge
Temperature
Average
Amp/Hour
Usage
Fridge
28
o
C
n/a
+4
o
C
0.7 A
Freezer
32
o
C
-25
o
C
+2
o
C
1.4 A
Freezer
43
o
C
-19
o
C
+4
o
C
2.3 A
Question 4
Is there any way to automatically switch the fridge off before the
battery becomes dangerously low?
Yes. The fridge requires either 12 or 24V to operate and
incorporates a computer-operated automatic cut off system.
This feature cuts out the fridge if the power source goes below
10.4V. Although this is a great safety utility Evakool advices
you to use your own good judgment before leaving your fridge
unattended.
Question 5
What do I do, if, in the unlikely event that my fridge stops?
There are many well-qualified service agents within Australia
who can service the Evakool Fridges refer to the listing on
the fridge page.
Ø Read the troubleshooting flowchart provided, the problem
faced may be easily rectified.
Ø Refer to the service manual
Ø Contact your nearest service centre
Seitenansicht 3
1 2 3 4 5 6 7

Kommentare zu diesen Handbüchern

Keine Kommentare